Walls-strong

Walls Support the Roof and other Loads-Part K

It is vital that walls are strong, stable, waterproof and fireproof. The way that the roof is affixed to the wall is also very important.

The fundamental structure of a house is formed by its external walls, which must support the roof and take any other load that is built above. The section of the National Building Regulations that deals with walls is SANS 10400-K  and it has several parts, each dealing with building walls, and the elements of how both internal and external walls should be correctly constructed.

Changes to the Legislation

Like much of SANS 10400, Part K: Walls has changed quite substantially, both in terms of the legislation and the section that deals with The application of the National Building Regulations, which is the document prepared by the SABS and published separately to the legislation.

(NOTE: Previously SABS 0400, which became SANS 10400, was published by the SABS in its entirety, with the legislation and a Code of Practice which took the form of “deemed-to-satisfy requirements”. When the legislation changed on May 30, 2008, this was gazetted. The SABS then progressively updated its guidelines and published them over a period of years, as a series of individual documents. These are available from offices of the SABS and from the Bureau’s webstore, HERE. The new version of Part K was published on 29-03-2011 and it costs R517.56 including VAT.)

This article deals primarily with the changes to the legislation, and how it applies to building walls, rather than the South African National Standards.

Structural Strength and Stability of Building Walls

Part K 1 of the regulations states that, “Any wall shall be designed and constructed to safely sustain any actions which can reasonably be expected to occur and in such a manner that any local damage (including cracking) or deformation do not compromise the opening and closing of doors and windows or the weather tightness of the wall and in the case of any structural wall, be capable of safely transferring such actions to the foundations supporting such wall.”

This has been substantially expanded. Previously the legislation simply said the walls should be capable of safely sustaining any loads to which they would be likely to be subjected. It also said that structural walls should be capable of safely transferring such loads to the foundation supporting a structural wall.

There are various walling materials available, made primarily from clay and cement-based products. You will need to decide which is the best material for your particular purposes. Walls can also be built with stone or timber, but each material has its own set of methods to satisfy the requirements.

Solid brick walls normally consist of two brick skins that are joined together and strengthened with brickforce or brick reinforcing and/or wall-ties (a mild steel wire laid between some of the courses to add strength). The interior and exterior surfaces are normally plastered but may be fairfaced (facebrick). Concrete block walls are a more economic option and are often used for garages and outbuildings.

Water Penetration of Walls

Whatever materials you choose to use when you build, the method used for building walls must comply with Part K 2 of the regulations. Primarily they must be built to prevent water penetrating into any part of the building. All cavity walls must be well drained by means of weep holes above a damp-proof course. All cement bricks and blocks are relatively porous and should be plastered or rendered on both sides for thorough waterproofing.

Basements and semi-basements are also referred to in the “new” legislation, and any room below ground must be adequately waterproofed.

The legislation reads: “Where a building includes a basement or semi-basement, the local authority may, if it considers that conditions on the site on which the building is to be erected necessitate integrated designs for the penetration of water into such basement or semi-basement applicable to all construction elements or components thereof, require the submission of such designs for approval. Construction shall be in accordance with the requirements of the approved design.”

In recent years, a variety of alternative construction methods have been developed, most notably in the sphere of cheaper housing. These include the building of walls with insulated fibrecement panels; with fibreglass panels; creating the basic structure with shuttered no-fines concrete; using polystyrene sprayed onto a basic framework; or piling up sausage-shaped bags of sand and cement. If you want to use any altrernative method it would be best to contact your local authority planning division, or building inspector, for guidance.

Roof Fixing

Part K 3 deals with the way in which the roof of any building is attached to the wall and states that this must be done securely and safely and must be able to withstand any natural forces such as high winds or rain and hail. Specifically, it states:

“Where any roof truss, rafter or beam is supported by any wall, provision shall be made to fix such truss, rafter or beam to such wall in a secure manner that will ensure than any actions to which the roof may normally be subjected will be transmitted to such wall.”

While this clause of the legislation is basically the same as it was previously – one word has changed with forces deleted and actions replacing it – there are substantial amendments to the so-called “deemed-to-satisfy requirements” published in SANS 10400, Part K Walls. Similarly there are many changes – more so in the form of additions – to SANS 10400, Part L Roofs.

The Ways Walls Behave in Fire

Part K 4 deals with Behaviour in Fire, and state simple that, “Any wall shall have combustibility and fire resistance characteristics appropriate to the location and use of such wall”.

Brick, block and stone walls are generally accepted as fire resistant. Timber frame with timber or fibrecement cladding need to be certified, and you should check with the supplier regarding these rules for their type of walling, before you decide which material you are going to use for building walls.

Deemed-to-Satisfy Requirements

Part K 5 of the legislation states that Parts K 1 to K 4 will have been deemed to be satisfied “where the structural strength and stability of any wall, the prevention of water penetration into or through such wall, the fixing of any roof to such wall, and the behavior in a fire of such wall” complies with the relevant part of SANS 10400. This standard, “Establishes deemed-to-satisfy solutions for rain penetration and damp-proofing and contains simple design and construction provisions for masonry walls in single-storey and double-storey buildings and framed buildings that do not exceed four storeys; masonry balustrade walls and masonry free-standing boundary, garden and retaining walls.”

Roofs-Part L